E. coli in water
What is  Escherichia coli

E. coli is a leading cause of waterborne bacterial contamination globally. Pathogenic strains cause severe gastrointestinal illness and kidney failure — making rapid, field-based detection essential for public health.

*WHO Global Burden of Foodborne Diseases, 2015 · CDC Water Quality Guidelines

🤢
Gastrointestinal Illness

Severe diarrhoea, cramps and vomiting — onset within 1–10 days of exposure

🫘
Kidney Failure (HUS)

Toxigenic strains cause Haemolytic Uraemic Syndrome, especially in children

💧
Waterborne Outbreaks

Contaminated drinking & recreational water are leading transmission vectors

🌍
~1.5M Deaths / Year

WHO-estimated annual deaths from waterborne faecal-contamination diseases

New Product

E. coli Water Quality Detection Kit

A rapid, field-ready system combining a pre-loaded microfluidic chip, portable LAMP reader, and mobile app — delivering high-sensitivity bacterial detection at the point of sampling.

10 CFU/mL detection limit
Water Safety · Bacterial Contamination

Certainty in
Every Drop

Detect E. coli contamination in field water samples with exceptional sensitivity. No lab required — collect, load, and read results in under an hour.

10
CFU/mL
Sensitivity
~60
Min
Total Time
4
Step
Workflow
Xfold MICROFLUIDIC CHIP CH1 CH2 CH3 Pre-loaded · Single-use · Field-ready
🧬

Xfold Microfluidic Chip

Pre-loaded with master mix, dye, and target primers. Drop-in ready for field use.

  • Real-time LAMP Amplification
  • Simultaneous Multiplex Detection
  • Optimised for field conditions
Smartphone 71 × 147 mm Xfold INSERT CHIP LAMP Reader 70 × 180 mm vs
📡

Portable Xfold LAMP Reader

Insert the chip, connect via Bluetooth, and press START. Real-time fluorescence tracking on your phone.

  • Compact, battery-powered reader
  • Live amplification curves
  • Bluetooth connectivity
Xfold Monitor RUNNING E. coli 223 187 152 116 80 0 12 24 36 48 60 Time (s) CH1 E.coli CH2 Salmonella ▶ START 💾 SAVE
📱

Mobile App & Automated Report

Real-time readout on your smartphone. Every test auto-generates a comprehensive, shareable PDF report.

  • Live LAMP curve on mobile
  • Auto-generated PDF report
  • Exportable audit record

How It Works

1
Collect Sample

Secure a field water sample from the target source

2
Lyse & Prepare

Transfer to tube, heat block at 100°C / 10 min

3
Load Chip

Pipette lysate into the pre-loaded Xfold chip

4
Read & Report

Insert into reader, tap START, get results & PDF report

CONTACT

Get in Touch

Contact us today about our E. coli rapid detection system for food safety and water quality applications.